Add to Cart
big current big power transformer PQ26 transformer for plant lighting stable function safe transformer
Features:
1. Custom designs available
2. High efficiency of over 95%
3. High frequency range 1KHz-1MHz
4. High isolation strength
5. High-temperature resistant
6. Operating temperature -40°C to +125°C
7. Power range 10w-500w
Application:
Power supply Driver
Lighting appliance
Communication equipment
LCD Power Supply
Converter and inverter
WINDING PARAMETER: | |||||||||||
WINDING ORDER | MATERIAL SPEC. | MARGINAL TAPE | TUBE TYPE | S--F | TURNS | WINDING FASHION |
ISOLATION BETWEEN WINDING | ||||
TOP | PIN | S | F | ||||||||
N1 | 2UEWFΦ0.4*1P | 1---3 | 17 | SPACED | 1mil*9.5mm/2TS | ||||||
N2 | TRW(B)Φ0.8*1P | TFL | TFL | 8,9---10,11 | 7 | SPACED | 1mil*9.5mm/2TS | ||||
N3 | 2UEWFΦ0.4*1P | TFL | 3---2 | 16 | SPACED | 1mil*9.5mm/2TS | |||||
N4 | 2UEWFΦ0.4*1P | 5---6 | 6 | SPACED | 1mil*9.5mm/3TS |
ELECTRICAL CHARACTERISTIC: | |||||||||||
NO. | ITEM | MEASURE POINT | TECHNICAL DATA | REMARK | |||||||
1 | INDUCTANCE | 1---2 | 216μH±15% | 100KHz 0.1V CH-1061 100Ω | |||||||
LK | 1---2(SHORT SEC) | 20μHMAX | 100KHz 0.1V CH-1061 100Ω | ||||||||
2 | DCR | 1---2 | 300mΩMAX | AT 25℃ | |||||||
3 | HI-POT | P---S | 4500VAC | 5mA 3Sec 50HZ | |||||||
P/S---CORE | 1500VAC | 5mA 3Sec 50HZ |
MATERIAL LIST: | |||||||||||
NO. | MATERIAL NAME | MATERIAL SPEC. | PROVIDER | UL·NO | |||||||
1 | CORE | PQ2620 TP4 | TDG OR EQUIVALENT | ||||||||
2 | BOBBIN | PHENOLIC | CHANG CHUN OR EQUIVALENT | E59481 | |||||||
3 | WIRE | MW-79C | DATONG OR EQUIVALENT | E237377 | |||||||
4 | WIRE | TRW(B) | GREAT HOLDING OR EQUIVALENT | E237377 | |||||||
5 | ISOLATION TAPE | CT-280 130℃ | YA HUA OR EQUIVALENT | E165111 | |||||||
6 | TUBE | TFL PTFE | WOER OR EQUIVALENT | E203950 | |||||||
7 | VARNISH | 8562(a) | HANG CHENG OR EQUIVALENT | E200154 |
General information:
It is recommended that the temperature of the part does not exceed +125°C under worst case conditions.
Storage Temperature: -40°C to 85°C
Operating Temperature: -40°C to 125°C
Test conditions of Electrical Properties: 20°C, 33% RH if not specified differently
OPERATING TEMPERATURE RANGE, PACKAGE QUANTITY, PRODUCT WEIGHT | |||||
Temperature range | Humidity range | Standard test conditions | |||
Operating temperature* | Storage temperature | Operating temperature** | Storage temperature** | Operating temperature** | Storage temperature** |
( ℃) | ( ℃) | ( % RH) | ( % RH) | ( ℃) | ( % RH) |
-30 to +120 | -40 to +80 | 10 to +95 | 10 to +95 | 25 ± 10 | 25 to +75 |
* With self-heating
** Maximum wet-bulb temperature 38°C, without dewing